Contact Us

If you have any questions, you can contact us. Required fields are marked *

ul 1 hour shaft wall assembly

UL Design U415 - 1, 2, 3, or 4 Hour Wall Assembly - BuildSite

UL Design U415 - 1, 2, 3, or 4 Hour Wall Assembly Documents (1) Add to Package Installation Instructions - UL Design U415 - 1, 2, 3, or 4 Hour Wall Assembly (454 Kb, 11pg) System

Learn More

UL U415 System G - Wall Assembly - Knauf Insulation North America

Assembly Details Gypsum Board 1" [25.4 mm] Sheetrock ® Gypsum Liner Panels (UL Type SLX) Steel Studs 2-1/2" [64 mm] CH studs, 20 ga. (0.033"), 24" [610 mm] O.C. Insulation 2-1/2" [64 mm] Knauf EcoBatt Insulation Gypsum Board 3 layers of 5/8" [15.9 mm] Sheetrock ® EcoSmart Gypsum Panel (UL Type ULIX ™) Notes View assembly information on UL Website.

Learn More

UL U415 System A - Wall Assembly - Knauf Insulation

UL U415 System A. Shaft Wall, Steel Stud (Non-Load-Bearing) · Stc. 0 · Fire Rating. 1 Hour · System Thickness. 4-5/8".

Learn More

BXUV.U469 - Fire-resistance Ratings - ANSI/UL 263 - BuildSite

Assembly Rating — 1 HR. Nonbearing Wall Gypsum Board* — 1 in. thick gypsum wallboard liner panels, supplied in nominal 24 in. or 600 mm 

Learn More

National Gypsum Company Fire-rated Assembly in ... - Macopa

UL Design. Head of Wall Firestop System. Page. Detail No. Title. SW Series - Shaftwall Assemblies 09 21 16.23. SW 101. 1 Hour Shaftwall Partition.

Learn More

What You Should Know About Cavity Shaftwalls - National Gypsum

11/1 · Can horizontal shaftwall assemblies be used for a rated corridor ceiling? Yes, National Gypsum has several options for rated horizontal systems: 2-hour rated UL Design G586 or 1- and 2-hour horizontal shaftwall assemblies per UL Evaluation Report: ER R3501-02 (Section 6.3.1). These are typical horizontal assemblies used in a fire-rated corridor.

Learn More

UL Design U469 - 1 Hour Wall Assembly - BuildSite

UL Design U469 - 1 Hour Wall Assembly Documents (1) Add to Package Installation Instructions - UL Design U469 - 1 Hour Wall Assembly (96 Kb, 5pg) System Package Hide Steel Studs "C-H"

Learn More

Fire Resistance - International Code Council

UL 263. ASTM. E119. Standards Used to Evaluate Assemblies Yes, this is a shaft wall. The rating – 1 Hour. ➢ The load capacity – Bearing. Wall 

Learn More

Shaft Wall Solutions for Wood-Frame Buildings: Codes & Detailing - Civil

Several options for 1- and 2-hour fire resistance-rated, wood-frame wall assemblies that could be useful for shafts are presented below. 1-Hour Single Wall UL U305 GA WP 3510 UL U311 IBC Table 721.1 (2), Item 14-1.3 UL U332 1-Hour Double Wall UL U341 2-Hour Single wall UL U301 UL U334 IBC Table 721.1 (2) Item Number 14-1.5

Learn More

1 hour UL penetration for structural I-beam thru shaft wall

1 hour UL penetration for structural I-beam thru shaft wall I need a UL assembly for a structural I-beam penetrating thru a one-hour shaft wall. Access would only be from double layer (c side) side of wall. If possible, some variation of W-L-7188 steel I-beam, UL Penetration Assemblies 0 1 Reply Nathan Jennings 1 Year ago Hilti Verified Hi James,

Learn More

Shaft Wall - Construction

Fire-Rated Assemblies 3 USG Shaft Wall Systems 09 20 00/USG BuyLine 2425 1 Hour Fire-rated Construction Non-loadbearing Acoustical Performance Construction Detail Description Test Number STC Test Number wt. 8 † 5/8 SHEETROCK® brand FIRECODE® Core gypsum UL

Learn More

ClarkDietrich Shaftwall Systems | ClarkDietrich Building Systems

Shaftwall systems are interior nonload-bearing fire rated wall assemblies that provide critical, life safety, fire-resistant protection for elevator shafts, stairwells, vertical chases and mechanical enclosures. Shaftwalls in elevators and stairwells are one of the most important wall assemblies in a building.

Learn More

UL Wall Assemblies, Fire Rated Wall Designs | USG - CGC Inc

USG's range of resources on UL wall assemblies can help with the planning and estimation of Chase Wall - Wood Stud (Load-Bearing). Fire Rating. 1 hours.

Learn More

CT Shaft Wall Stud System Catalog_070622.indd - CEMCO

and gypsum Shaftliner manufacturers are approved in several UL fire- rated assemblies for both 1 and 2-hour ratings . ASTM & Code Standards. • ICC-ESR 4934.

Learn More

Q&A: Area Separation Wall Design | UL Solutions

12/2 · The area separation wall consists of two layers of 1 in. thick gypsum liner boards, secured through the use of floor, ceiling and intermediate horizontal C channels, and vertical H

Learn More

Shaftwall & Stairwell Systems - PABCO Gypsum

1” PABCORE® Shaftliner, Type X 1” (25.4mm) 24” (610mm) 8’ (2428mm) 10’ (3048mm) 12’ (3658mm) Double Beveled 4.1 lbs/ft2 N/A 1” MOLD CURB® Plus Shaftliner, Type X 1” (25.4mm) 24” (610mm) 8’ (2428mm) 10’ (3048mm) 12’ (3658mm) Double Beveled 4.1 lbs/ft2 10 (Highest Rating) 1” PABCO GLASS® Shaftliner, Type X

Learn More

UL Wall Assemblies, Fire Rated Wall Designs - USG

USG's range of resources on UL wall assemblies can help with the planning and Shaft Wall - Steel Stud (Non-Load-Bearing). Fire Rating. 1 hours.

Learn More

Shaft Wall Solutions For Wood-Frame Buildings - WoodWorks

were to fail at 1 hour, the wall above could not continue UL U334. FIGURE 5: Shaftliner Wall Assembly with Wood Wall Each Side. FIGURE 6:.

Learn More

UL Wall Assemblies with STC and Fire Ratings - Knauf Insulation North

Find resources and details for UL rated wall systems with the required STC and fire ratings for your project. Products Products > Pipe Insulation. Batts. Pipe and Tank . Blown-in Insulation. Board. UL Wall Assemblies BIM - Revit Library Transparency Catalog > NAIMA 3E Plus FAQs Technical Support

Learn More

2-hr. Fire Rated Wall Construction Overview - Henrico County

The two layers of 1″ gypsum shaft liner provides the 2 hour rating, and Many 1-hr. rated wall assemblies listed in UL will allow.

Learn More

Ul u529 shaft wall - zsi.szaffer.pl

A 2-hour fire-resistive, non-load bearing non-combustible partition designed to enclose shaftwalls, containing elevators, ducts, piping, air shafts and similar construction applications. System consists of 1" shaftliner panels supported by 2-1/2", 4" or 6" C-T studs and faced on one side with two layers of 1/2" Type C or 5/8" Type X gypsum board.

Learn More